Cool, Thank you! This solves my query. Just one more thing, could you link to a sample 4CC command that I could use to query such information?
↧
Forum Post: RE: TIDA-050047: Query Battery / charging /discharging information from TPS25750 connected to host
↧
Forum Post: UC3845: uc3845
Part Number: UC3845 Tool/software: Let me know, does TI make UC3845 (Current-Mode PWM Controller) has soft start functionality?
↧
↧
Forum Post: RE: TIDA-050047: Query Battery / charging /discharging information from TPS25750 connected to host
Hassan, I would not be able to get you sample i2c traces in the next few days. Will keep you posted. Regards, Deepak
↧
Forum Post: RE: PSPICE-FOR-TI: What is the process to migrate my Pspice for TI license to a new computer?
I'll get it submitted. You should get a notification by Friday that it is done. David
↧
Forum Post: RE: PSPICE-FOR-TI: PSPICE-FOR-TI
Hi Arun, I'll have to disable your old installs. Can I disable all, or do you need to keep any active? David
↧
↧
Forum Post: RE: PSPICE-FOR-TI: Netlist error
Hi Preethi, Please archive and post your project here. I'll see if I can reproduce the error and find a solution. David
↧
Forum Post: RE: PSPICE-FOR-TI: Netlist error
Also, can you post the error message here to help debug?
↧
Forum Post: TIDA-00707: Firmware Files of TIDA-00707
Part Number: TIDA-00707 Other Parts Discussed in Thread: UCD3138A , PMP10804 Tool/software: Hello, As per user guide tidubk8b , technical documentation for UCD3138A based 1kW PFC firmware files should be explained in PMP10804 test results. But the PMP10804 is a flyback converter. Kindly share the correct document. Regards, Nikhil.
↧
Forum Post: RE: UCC28742: Not getting required Output.
We have taken the reference of mentioned design report which is generated from WENBENCH TI. Moreover, we have set the parameters of transformer and other components suggested in design report. However, we still not getting the desire output. Therefore, kindly suggest that in which section we need to work for resolving the problem. e2e.ti.com/.../85to265VInput_5F00_1000VFlybackConverterDesign.pdf
↧
↧
Forum Post: RE: UCC28742: Not getting required Output.
Hi, Webench is just a starting point - you need to debug your converter to find where the issue is not able to reach 1000V. You need to capture the waveforms to see how the transformer works like to decide if your transformer and your converter work like your design and then tune up accordingly. You need to measure the waveform of each portion of your converter to find where need to tune up, such as Vds, transformer secondary-side waveform, CS pin, OUT pin, etc. to help your debugging.
↧
Forum Post: RE: UC3845: uc3845
UC3845 does not have soft start. Here is the filtered parametric list of general purpose PWMs (GPPWM) that include integrated soft start. For GPPWMs that do not include soft start feature, it can be added externally according to RC time constant applied to the COMP as shown below. Regards, Steve
↧
Forum Post: RE: LAUNCHXL-F28P65X: Control Card F28P65X
Hi, There is a console window which displays the compilation log. Pls share it. It would help in identifying the compilation issues/errors. Best Regards Siddharth
↧
Forum Post: RE: PMP23338: PMP23338 CCS
Hi, if you use Kool Mu Max (P/N: 79894A7HT19) to do the calculation, you will get ~240uH. AL of the Kool Mu Max core is 120nH/T^2. With 44turns, you get 232uH. Regards, Sheng-Yang Yu
↧
↧
Forum Post: RE: LAUNCHXL-F28P65X: Control Card F28P65X
Hi Siddharth , I manage to fix the error from some technical assistance from senior embedded engineer. It was more related to the Sysconfig file format. I replace the format with right choosen borard/device "docking station". It's working well now. Thank you for assistance. Good day
↧
Forum Post: RE: LM2576HV: LM2576HVS- ADJ/NOPB and LM2576HVSX- ADJ/NOPB
Hello We have a few more questions: Reflow Atmosphere Does the customer reflow the parts under inert atmosphere (N2 blanket) or normal atmosphere (CDA or normal air)? Reflow Temperature What is the unit# on the PCB for our device? R32, U11 or D5? If it were U11, the peak temperature was > 250C. For the form factor of this device, the recommended peak reflow temperature is 245 +5/-0C. Thanks
↧
Forum Post: RE: PSPICE-FOR-TI: Netlist error
Cannot post the project. Could you help in any other way.
↧
Forum Post: RE: TIDA-00707: Firmware Files of TIDA-00707
Hi, Nikhil, You are right, PMP10804 is the document for other design. This is typo, and thanks for pointing out. We will correct it. Regards, Sean
↧
↧
Forum Post: PSPICE-FOR-TI: ERROR(ORNET-1163)
Part Number: PSPICE-FOR-TI Tool/software: Hi Team, Good day! Please help to check the following error for this simulation. When the customer tried to simulate they got this error ERROR(ORNET-1163): Unable to create netlist file. Let me know if you need more information to proceed with your troubleshooting. Thank you in advance. Regards, Jonathan
↧
Forum Post: RE: PSPICE-FOR-TI: Netlist error
You can send it to my email address. d-larkin@ti.com
↧
Forum Post: PSPICE-FOR-TI: PSPICE-FOR-TI
Part Number: PSPICE-FOR-TI Tool/software: Hello, I am currently trying to simulate a bode analysis and a load transient waveform. When I go to run the simulation, the new window where the simulation would usually be pops up, but nothing simulates. I think my simulation profile settings are wrong, but I am unsure as what to change. Thank you.
↧