Forum Post: RE: why does CCS uses "-romwidth 16" as default option for creating TI-TXT?

$
0
0

Okayama,

Here is some additional clarification from our hex converter experts.  We will be updating our user guide documentation with below:

- For TI-TXT files, the rom-width parameter is ignored since data is always written in byte format in TI-TXT files, so it doesn’t really matter what we specify for this parameter

- For TI-Tagged format the width must always be set to 16-bits and hex430 returns with an error code if 8-bit width is selected.

Regards,

Greg